Ethernet Interface
-
Cabling Direction
- Front cabling
-
Compatible Modules
- Slot 1/2/3:
PM-7200-8TX
PM-7200-2MSC4TX
PM-7200-2MST4TX
PM-7200-2SSC4TX
PM-7200-4MSC2TX
PM-7200-4MST2TX
PM-7200-4SSC2TX
PM-7200-6MSC
PM-7200-6MST
PM-7200-6SSC
PM-7200-8SFP
PM-7200-4M12
PM-7200-8MTRJ
PM-7200-4TX-PTP (PT-7728-PTP only)
PM-7200-4MST-PTP (PT-7728-PTP only)
PM-7200-4MSC-PTP (PT-7728-PTP only)Slot 4:
PM-7200-4GTXSFP
PM-7200-2GTXSFP
PM-7200-4GSFP-PHR-PTP (PT-7728-PTP only)
PM-7200-4GTX-PHR-PTP (PT-7728-PTP only)
PM-7200-1BNC2MST-PTP (PT-7728-PTP only)
- Slot 1/2/3:
-
Standards
- IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN Tagging
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1X for authentication
IEEE 802.3 for 10BaseT
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3ad for Port Trunk with LACP
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for flow control
IEEE 802.3z for 1000BaseSX/LX/LHX/ZX
- IEEE 802.1D-2004 for Spanning Tree Protocol
Ethernet Software Features
-
Filter
- 802.1Q, GMRP, GVRP, IGMP v1/v2c, QinQ VLAN, VLAN unaware
-
Industrial Protocols
- EtherNet/IP, Modbus TCP
-
Management
- Back Pressure Flow Control, BOOTP, DHCP Option 66/67/82, DHCP Server/Client, Flow control, HTTP, IPv4/IPv6, LLDP, Port Mirror, RARP, RMON, SMTP, SNMP Inform, SNMPv1/v2c/v3, Syslog, Telnet, TFTP, Fiber check
-
MIB
- Bridge MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB, Q-BRIDGE MIB, RMON MIB Groups 1, 2, 3, 9, RSTP MIB
-
Power Substation
- IEC 61850 QoS, MMS
-
Redundancy Protocols
- Link Aggregation, MSTP, RSTP, STP, Turbo Chain, Turbo Ring v1/v2, HSR, PRP
-
Security
- Broadcast storm protection, HTTPS/SSL, TACACS+, Port Lock, RADIUS, Rate Limit, SSH
-
Time Management
- NTP Server/Client, SNTP, IEEE 1588 PTP v1/v2 (hardware-based)
Switch Properties
-
IGMP Groups
- 256
-
Max. No. of VLANs
- 64
-
VLAN ID Range
- VID 1 to 4094
-
Priority Queues
- 4
Serial Interface
-
Console Port
- RS-232 (RJ45)
Input/Output Interface
-
Alarm Contact Channels
- Resistive load: 3 A @ 30 VDC, 240 VAC
Power Parameters
-
Input Voltage
- 48 VDC (36 to 72 VDC), 110/220 VAC/VDC (85 to 264 VAC, 88 to 300 VDC)
-
Overload Current Protection
- Supported
-
Reverse Polarity Protection
- Supported
-
Connection
- 10-pin terminal block
-
Input Current
- 0.49/0.26 A @ 110/220 VAC
0.59/0.30 A @ 110/220 VDC
- 0.49/0.26 A @ 110/220 VAC
Physical Characteristics
-
Housing
- Aluminum
-
IP Rating
- IP30
-
Dimensions (without ears)
- 440 x 44 x 325 mm (17.32 x 1.73 x 12.80 in)
-
Weight
- 5900 g (13.11 lb)
-
Installation
- 19-inch rack mounting
Environmental Limits
-
Operating Temperature
- -40 to 85°C (-40 to 185°F)
Note: Cold start requires minimum of 100 VAC @ -40°C
- -40 to 85°C (-40 to 185°F)
-
Storage Temperature (package included)
- -40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
- 5 to 95% (non-condensing)
Standards and Certifications
-
Safety
- UL 60950-1
-
EMI
- EN 55032 Class A, CISPR 32, FCC Part 15B Class A
-
EMS
- IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 35 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
IEC 61000-4-11 DIPs
- IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
-
Power Substation
- IEC 61850-3, IEEE 1613
-
Railway
- EN 50121-4, EN 50155 (complies with a portion of EN 50155 specifications)
-
Traffic Control
- NEMA TS2
MTBF
-
Time
- 393,828 hrs
-
Standards
- Telcordia SR332
Warranty
-
Warranty Period
- 5 years