Ethernet Interface
-
10/100BaseT(X) Ports (M12 D-coded 4-pin female connector)
5
-
Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3x for flow control
Power Parameters
-
Input Current
0.1 A @ 24 VDC, 0.08 A @ 36 VDC
-
Input Voltage
18 to 30 VAC (47 to 63 Hz), 24 to 36 VDC
-
Inrush Current (Max.)
0.28 A @ 24 VDC
-
No. of Power Inputs
1
-
Operating Voltage
18 to 30 VAC
12 to 45 VDC -
Power Connector
M12 A-coded male connector
Physical Characteristics
-
Housing
Plastic top cover, metal bottom plate
-
IP Rating
IP67
-
Dimensions
60 x 125 x 29.6 mm (2.36 x 4.92 x 1.09 in)
-
Weight
Packaged: 270 g (0.56 lb)
-
Installation
DIN-rail mounting (with optional kit), Wall mounting
Environmental Limits
-
Operating Temperature
TN-5305: -25 to 60°C (-13 to 140°F)
TN-5305-T: -40 to 75°C (-40 to 167°F) -
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
5 to 95% (non-condensing)
-
Altitude
2000 m
Standards and Certifications
-
Freefall
IEC 60068-2-32
-
EMC
EN 55032/24
-
EMI
CISPR 32, FCC Part 15B Class A
-
EMS
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF -
Environmental Testing
IEC 60068-2-1, EN 50155
IEC 60068-2-14, EN 50155
IEC 60068-2-2, EN 50155
IEC 60068-2-30, EN 50155 -
International Approval
RCM
-
Railway
EN 50121-4, EN 50155
-
Railway Fire Protection
EN 45545-2
-
Safety
EN 60950-1, UL 508
-
Salt Spray Test
IEC 60068-2-11, EN 50155
-
Shock
IEC 60068-2-27, IEC 61373, EN 50155
-
Vibration
IEC 60068-2-64, IEC 61373, EN 50155
Declaration
-
Green Product
RoHS, CRoHS, WEEE
MTBF
-
Time
3,451,678 hrs
-
Standards
Telcordia SR332
Warranty
-
Warranty Period
5 years