Ethernet Interface
-
10/100BaseT(X) Ports (RJ45 connector)
EDS-2016-ML: 16
EDS-2016-ML-T: 16
EDS-2016-ML-MM-SC: 14
EDS-2016-ML-MM-SC-T: 14
EDS-2016-ML-MM-ST: 14
EDS-2016-ML-MM-ST-T: 14
EDS-2016-ML-SS-SC: 14
EDS-2016-ML-SS-SC-T: 14Auto negotiation speed
Full/Half duplex mode
Auto MDI/MDI-X connection -
100BaseFX Ports (multi-mode SC connector)
EDS-2016-ML-MM-SC: 2
EDS-2016-ML-MM-SC-T: 2 -
100BaseFX Ports (multi-mode ST connector)
EDS-2016-ML-MM-ST: 2
EDS-2016-ML-MM-ST-T: 2 -
100BaseFX Ports (single-mode SC connector)
EDS-2016-ML-SS-SC: 2
EDS-2016-ML-SS-SC-T: 2 -
Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3x for flow control
IEEE 802.1p for Class of Service
DIP Switch Configuration
-
Ethernet Interface
Quality of Service (QoS)
Broadcast storm protection
Port break alarm
Input/Output Interface
-
Alarm Contact Channels
Relay output with current carrying capacity of 1 A @ 24 VDC
Switch Properties
-
MAC Table Size
8 K
-
Packet Buffer Size
2 Mbits
-
Processing Type
Store and Forward
Power Parameters
-
Connection
1 removable 6-contact terminal block(s)
-
Input Current
EDS-2016-ML: 0.088 A @ 24 VDC
EDS-2016-ML-MM-SC: 0.149 A @ 24 VDC
EDS-2016-ML-MM-ST: 0.152 A @ 24 VDC
EDS-2016-ML-SS-SC: 0.163 A @ 24 VDC -
Input Voltage
12/24/48 VDC
Redundant dual inputs -
Operating Voltage
9.6 to 60 VDC
-
Overload Current Protection
Supported
-
Reverse Polarity Protection
Supported
Physical Characteristics
-
Housing
Metal
-
IP Rating
IP30
-
Dimensions
EDS-2016-ML: 36 x 135 x 95 mm (1.41 x 5.31 x 3.74 in)
EDS-2016-ML-MM-SC: 58 x 135 x 95 mm (2.28 x 5.31 x 3.74 in) -
Weight
Non-fiber models: 486 g (1.07 lb)
Fiber models: 648 g (1.43 lb) -
Installation
DIN-rail mounting
Wall mounting (with optional kit)
Environmental Limits
-
Operating Temperature
EDS-2016-ML: -10 to 60°C (14 to 140°F)
EDS-2016-ML-T: -40 to 75°C (-40 to 167°F) -
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
5 to 95% (non-condensing)
Standards and Certifications
-
Safety
UL 61010-2-201
EN 62368-1(LVD) -
EMC
EN 55032/35
EN 61000-6-2/-6-4 -
EMI
CISPR 32, FCC Part 15B Class A
-
EMS
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 MHz: 20 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF -
Hazardous Locations
Class I Division 2
ATEX
IECEx -
Railway
EN 50121-4
-
Vibration
IEC 60068-2-6
-
Shock
IEC 60068-2-27
-
Freefall
IEC 60068-2-32
-
Maritime
DNV
LR
ABS
NK
MTBF
-
Time
2,070,826 hrs
-
Standards
Telcordia (Bellcore), GB
Warranty
-
Warranty Period
5 years