Product Overview
Suitable Applications | Horizontal and building backbone cable; Support current and future Category 5e applications, such as 1000Base-T (Gigabit Ethernet), 100 Base-T, 10 Base-T, FDDI, and ATM, suitable for outdoor use |
---|
Construction Details
CONDUCTOR
Element | Size | Stranding | Material | No. of Pairs |
---|---|---|---|---|
Individual Pair | 24 | Solid | BC – Bare Copper | 4 |
INSULATION
Element | Material | Nom. Insulation Diameter | Color Code |
---|---|---|---|
Individual Pair | PE – Polyethylene | 0.9 mm (0.035 in) | White/Blue & Blue, White/Green & Green, White/Orange & Orange, White/Brown & Brown |
OUTER JACKET
Material | Nom. Diameter |
---|---|
PE – Polyethylene | 4.7 mm (0.19 in) |
Electrical Characteristics
ELECTRICALS
Max. Conductor DCR | Max. Mutual Capacitance | Max. Capacitance Unbalance | Nom. Characteristic Impedance |
---|---|---|---|
95 Ohm/km (29 Ohm/1000ft) | 56 pF/m (17 pF/ft) | 160 pF/100m | 100 Ohm |
DELAY
Max. Delay Skew | Nom. Velocity of Prop. |
---|---|
40 ns/100m | 70% |
HIGH FREQUENCY
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Min. TCL [dB] | Min. ELTCTL [dB] |
---|---|---|---|---|---|---|---|---|---|---|
1 | 2.1 dB/100m | 65.3 | 62.3 | 63.2 | 60.2 | 64 | 61 | 20 | 40 | 35 |
4 | 4 dB/100m | 56.3 | 53.3 | 52.32 | 49.3 | 52 | 49 | 23 | 34 | 23 |
10 | 6.3 dB/100m | 50.3 | 47.3 | 44 | 41 | 44 | 41 | 25 | 30 | 15 |
16 | 8 dB/100m | 47.2 | 44.2 | 39.2 | 36.2 | 39.9 | 36.9 | 25 | 28 | 10.9 |
20 | 9 dB/100m | 45.8 | 42.8 | 36.8 | 33.8 | 38 | 35 | 25 | 27 | 9 |
31.25 | 11.4 dB/100m | 42.9 | 39.9 | 31.5 | 28.5 | 34.1 | 31.5 | 23.6 | 25.1 | 5.5 |
62.5 | 16.5 dB/100m | 38.4 | 35.4 | 21.9 | 18.9 | 28.1 | 25.1 | 21.5 | 22 | |
100 | 21.3 dB/100m | 35.3 | 32.3 | 14 | 11 | 24 | 21 | 20.1 | 20 |
Table Notes | Limits below 4 MHz are for information only. Reference standard: IEC 61156-5 |
---|
VOLTAGE
Voltage Rating |
---|
72 V DC |
Mechanical Characteristics
TEMPERATURE
Operating | Installation |
---|---|
-30°C To +60°C | 0°C To +50°C |
BEND RADIUS
Installation Min. |
---|
40 mm (1.6 in) |
Max. Pull Tension | 65 N (15 lbf) |
---|---|
Bulk Cable Weight | 27 kg/km (18 lbs/1000ft) |
Standards and Compliance
Environmental Suitability | Outdoor |
---|---|
CPR Compliance | CPR Euroclass: Fca |
IEEE Compliance | PoE: IEEE 802.3bt Type 1, Type 2, Type 3 |
Data Category | Category 5e |
ISO/IEC Compliance | ISO/IEC 11801-1 |
CENELEC Compliance | EN 50173-1, Segregation class according to EN50174-2 = a |
Product Notes
Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. |
---|