Product Overview
Suitable Applications | RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, …); Low Voltage Digital Control (24v, …); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over a long distance, etc. |
---|
Construction Details
CONDUCTOR
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Pair(s) | 2 | 24 AWG | 7×32 | TC – Tinned Copper |
INSULATION
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Pair(s) | PE – Polyethylene | 0.022 in (0.56 mm) | 0.068 in (1.7 mm) | White/Blue Stripe & Blue/White Stripe, White/Orange Stripe & Orange/White Stripe |
OUTER SHIELD
Shield Type | Material | Coverage | Drainwire Type |
---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7×32) TC |
Braid | Tinned Copper (TC) | 90% |
OUTER JACKET
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC – Polyvinyl Chloride | 0.035 in (0.89 mm) | 0.340 in (8.64 mm) |
Table Notes | Jacket OD +/- 0.025 |
---|---|
Overall Cable Diameter (Nominal) | 0.340 in (8.64 mm) |
Electrical Characteristics
ELECTRICALS
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedance | Nom. The velocity of Prop. | Max. Current |
---|---|---|---|---|---|---|
Pair(s) | 24 Ohm/1000ft | 12.8 pF/ft (42.0 pF/m) | 23 pF/ft | 120 Ohm | 66% | 2.1 Amps per Conductor at 25ºC |
Nom. Outer Shield DCR | 2.2 Ohm/1000ft (7.2 Ohm/km) |
---|
HIGH FREQUENCY (NOMINAL/TYPICAL)
Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
---|---|---|
Pair(s) | 1 | 0.6 dB/100ft |
VOLTAGE
UL Voltage Rating |
---|
300 V (CM), 30 V (UL AWM 2919) |
Mechanical Characteristics
TEMPERATURE
UL Temperature | Operating |
---|---|
80°C | -30°C to +80°C |
BEND RADIUS
Stationary Min. | Installation Min. |
---|---|
3.5 in (89 mm) | 3.5 in (89 mm) |
Max. Pull Tension | 87 lbs (39 kg) |
---|---|
Bulk Cable Weight | 49 lbs/1000ft |
Standards and Compliance
Environmental Suitability | Indoor |
---|---|
Flammability / Reaction to Fire | UL 1685 UL Loading, IEC 60332-1-2 |
CPR Compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
NEC / UL Compliance | Article 800, CM |
AWM Compliance | AWM 2919 |
CEC / C(UL) Compliance | CM |
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
UK Regulation Compliance | UKCA Mark |
APAC Compliance | China RoHS II (GB/T 26572-2011) |
Other Standard Compliance(s) | DMX-512 |
Plenum Number | 82842, 89842 |
Non-Plenum Number | 9841ZH |