Product Overview
| Suitable Applications | Premise Backbone Cable |
|---|
Physical Characteristics (Overall)
CONDUCTOR
| AWG | Stranding | Material | No. of Pairs |
|---|---|---|---|
| 24 | Solid | BC – Bare Copper | 100 |
| Conductor Count | 200 |
|---|---|
| Total Number of Pairs | 100 |
INSULATION
| Material |
|---|
| PO – Polyolefin (Foam) |
| Bonded-Pair | N/A |
|---|
COLOR CHART
| Number | Color |
|---|---|
| 1 | White & Blue |
| 2 | White & Orange |
| 3 | White & Green |
| 4 | White & Brown |
| 5 | White & Slate |
| 6 | Red & Blue |
| 7 | Red & Orange |
| 8 | Red & Green |
| 9 | Red & Brown |
| 10 | Red & Slate |
| 11 | Black & Blue |
| 12 | Black & Orange |
| 13 | Black & Green |
| 14 | Black & Brown |
| 15 | Black & Slate |
| 16 | Yellow & Blue |
| 17 | Yellow & Orange |
| 18 | Yellow & Green |
| 19 | Yellow & Brown |
| 20 | Yellow & Slate |
| 21 | Violet & Blue |
| 22 | Violet & Orange |
| 23 | Violet & Green |
| 24 | Violet & Brown |
| 25 | Violet & Slate |
| Group One Binder | White/Blue |
| Group Two Binder | White/Orange |
| Group Three Binder | White/Green |
| Group Four Binder | White/Brown |
COLOR CHART 2
| Number | Color |
|---|---|
| 1 | Blue/White |
| 2 | Orange/White |
| 3 | Green/White |
| 4 | Brown/White |
OUTER SHIELD
| Material |
|---|
| Aluminum |
OUTER JACKET
| Material | Nominal Diameter | Ripcord |
|---|---|---|
| PVC – Polyvinyl Chloride | 0.850 in | Yes |
Construction and Dimensions
ARMOR
| Type of Armor | Material | Thickness of Armoring Tape |
|---|---|---|
| Corrugated | Aluminum | .008 in |
Electrical Characteristics
CONDUCTOR DCR
| Max. Conductor DCR | Max. DCR Unbalance |
|---|---|
| 93.8 Ohm/km | 5 % |
CAPACITANCE
| Max. Capacitance Unbalance | Nom.Mutual Capacitance |
|---|---|
| 330 pF/100m | 17 pF/ft |
DELAY
| Frequency [MHz] | Max. Delay | Max. Delay Skew | Nominal Velocity of Propagation (VP) [%] |
|---|---|---|---|
| 16 MHz | 543 ns/100m | 45 ns/100m | 68% |
HIGH FREQUENCY
| Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. RL (Return Loss) [dB] | Max./Min. Fitted Impedance |
|---|---|---|---|---|---|---|---|
| 0.772 MHz | 2.2 dB/100m | 47.0 dB | 43.0 dB | 50.1 dB | 46.1 dB | 100 +/- 15 | |
| 1.0 MHz | 2.6 dB/100m | 45.0 dB | 41.0 dB | 47.8 dB | 43.8 dB | 12.0 dB | 100 +/- 15 |
| 4.0 MHz | 5.6 dB/100m | 36.0 dB | 32.0 dB | 36.0 dB | 32.0 dB | 12.0 dB | 100 +/- 15 |
| 8.0 MHz | 8.5 dB/100m | 31.0 dB | 27.0 dB | 28.3 dB | 24.3 dB | 12.0 dB | 100 +/- 15 |
| 10.0 MHz | 9.7 dB/100m | 30.0 dB | 26.0 dB | 26.2 dB | 22.2 dB | 12.0 dB | 100 +/- 15 |
| 16.0 MHz | 13.1 dB/100m | 27.0 dB | 23.0 dB | 20.1 dB | 16.1 dB | 10.0 dB | 100 +/- 15 |
VOLTAGE
| UL Voltage Rating |
|---|
| 300 V RMS |
Temperature Range
| Installation Temperature Range | -20°C To +60°C |
|---|---|
| UL Temp Rating | 60°C |
| Storage Temperature Range | -30°C To +60°C |
| Operating Temperature Range | -30°C To +60°C |
Mechanical Characteristics
| Bulk Cable Weight | 414 lbs/1000ft |
|---|---|
| Max. Pull Tension | 600 lbs |
| Min. Bend Radius During Installation | 17.0 in |
| Min. Bend Radius/Minor Axis | 8.5 in |
Standards
| NEC/(UL) Compliance | CMR |
|---|---|
| CEC/C(UL) Compliance | CMR |
| CPR Euroclass | Eca |
| Data Category | Category 3 |
| ANSI Compliance | S-90-661-2012 Category 3, ANSI/NEMA WC-63.1 Category 3 |
| TIA/EIA Compliance | ANSI/TIA-568-C.2 Category 3 |
Applicable Environmental and Other Programs
| Environmental Space | Riser |
|---|---|
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/96/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU Directive Compliance | Yes |
| EU CE Mark | Yes |
| EU REACH SVHC Compliance (yyyy-mm-dd) | 2017-07-10 |
| MII Order #39 (China RoHS) | Yes |
Suitability
| Suitability – Aerial | No |
|---|---|
| Suitability – Burial | No |
| Suitability – Hazardous Locations | No |
| Suitability – Indoor | Yes |
| Suitability – Non-Halogenated | No |
| Suitability – Oil Resistance | No |
| Suitability – Outdoor | No |
| Suitability – Sunlight Resistance | No |
Flammability, LS0H, Toxicity Testing
| CSA/C(UL) Flammability | FT4 |
|---|---|
| UL Flammability | UL 1666 Riser |
| IEC Flammability | IEC 60332-1-2 |
| UL voltage rating | 300 V RMS |
Plenum/Non-Plenum
| Plenum (Y/N) | No |
|---|
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings. Corrugated Aluminum Armor Bonded to the Jacket. |
|---|