Product Overview
| Suitable Applications | For use in railway applications such as rolling stock, buses, or other vehicles, cable meets the requirements of the relevant parts of international railway standards like DIN 5510-2, EN 50153, EN 50155, EN 50305, and EN 45545-2, ECE R118.03 |
|---|
Construction Details
CONDUCTOR
| Size | Stranding | Material | No. of Pairs | No. of Elements |
|---|---|---|---|---|
| 24 AWG | 19×36 | TC – Tinned Copper | 4 | 8 |
INSULATION
| Material | Color Code | Notes |
|---|---|---|
| PO – Polyolefin (Foam) | White & Blue, White & Orange, White & Green, White & Brown | eBeam Cross-Linked |
CABLE CORE
| Description |
|---|
| 4 pairs twisted together |
INNER SHIELD
| Element | Shield Type | Material |
|---|---|---|
| Individual Shielded Pair | Tape | Bi-Laminate (Alum+Poly) |
| Table Notes | Aluminum facing outside |
|---|
OUTER SHIELD
| Shield Type | Material | Coverage |
|---|---|---|
| Braid | Tinned Copper (TC) | 80% |
OUTER JACKET
| Material | Nom. Diameter |
|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant, Thermoset) | 8.1 mm (0.32 in) |
| Table Notes | e-Beamed to Cross-link, cable meets the smoke test of LU 1-085 |
|---|---|
| Overall Cable Diameter (Nominal) | 8.1 mm (0.32 in) |
Electrical Characteristics
ELECTRICALS
| Max. Conductor DCR | Max. Mutual Capacitance | Max. Capacitance Unbalance | Nom. Characteristic Impedance |
|---|---|---|---|
| 95 Ohm/km | 56 pF/m (17 pF/ft) | 160 pF/100m | 100 Ohm |
DELAY
| Max. Delay Skew | Nom. Velocity of Prop. |
|---|---|
| 25 ns/100m | 78% |
HIGH FREQUENCY
| Frequency [MHz] | Max. Insertion Loss (Attenuation) |
|---|---|
| 1 | 2.9 dB/100m |
| 4 | 5.6 dB/100m |
| 10 | 8.8 dB/100m |
| 16 | 11.1 dB/100m |
| 31.2 | 15.6 dB/100m |
| 62.5 | 22.3 dB/100m |
| 100 | 28.5 dB/100m |
| 300 | 51.3 dB/100m |
| 600 | 75.1 dB/100m |
| 1000 | 100.4 dB/100m |
| Table Notes | Limits below 4MHz are for information only. Values at 1000 MHz are for information only |
|---|
| Transfer Impedance Class | Grade 1 |
|---|---|
| Table Notes | IEC 61156-5 |
| Screening Class | Type I |
|---|---|
| Table Notes | Coupling attenuation |
VOLTAGE
| Voltage Rating |
|---|
| 300 V |
Mechanical Characteristics
TEMPERATURE
| Operating | Storage |
|---|---|
| -40°C to +90°C | -40°C to +90°C |
| Table Notes | Flexible installation temperature range: -5°C To +90°C |
|---|
BEND RADIUS
| Stationary Min. | Installation Min. |
|---|---|
| 32 mm (1.3 in) | 64 mm |
Standards and Compliance
| Environmental Suitability | Indoor, Oil Resistance |
|---|---|
| Flammability / Reaction to Fire | IEC 60332-1-2, IEC 60332-2-25, UN ECE R118.03 |
| Data Category | Category 7 |
| ISO/IEC Compliance | ISO/IEC 11801-1 |
| CENELEC Compliance | EN 45545-2, Segregation class according to EN50174-2 = d |
| European Halogen-Free Standards | IEC 60754-1 – Halogen Amount = Zero, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3 |
| European Directive Compliance | EU CE Mark |
