Ethernet Interface
-
PoE Ports (10/100BaseT(X), RJ45 connector)
- 4
-
10/100/1000BaseT(X) Ports (RJ45 connector)
- 2
-
100/1000BaseSFP Slots
- 2
-
Standards
- IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
IEEE 802.3x for flow control
IEEE 802.3ad for Port Trunk with LACP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1p for Class of Service
IEEE 802.1X for authentication
- IEEE 802.3 for 10BaseT
Ethernet Software Features
-
Filter
- GMRP
GVRP
GARP
802.1Q VLAN
IGMP Snooping v1/v2/v3
IGMP Querier
- GMRP
-
Management
- IPv4/IPv6
Flow control
Back Pressure Flow Control
DHCP Server/Client
ARP
RARP
LLDP
Port Mirror
Linkup Delay
SMTP
SNMP Trap
SNMP Inform
SNMPv1/v2c/v3
RMON
TFTP
SFTP
HTTP
HTTPS
Telnet
Syslog
Private MIB
- IPv4/IPv6
-
MIB
- P-BRIDGE MIB
Q-BRIDGE MIB
IEEE8021-SPANNING-TREE-MIB
IEEE8021-PAE-MIB
IEEE8023-LAG-MIB
LLDP-EXT-DOT1-MIB
LLDP-EXT-DOT3-MIB
SNMPv2-MIB
RMON MIB Groups 1, 2, 3, 9
- P-BRIDGE MIB
-
Redundancy Protocols
- STP
RSTP
Turbo Ring v2
Turbo Chain
Ring Coupling
Dual-Homing
Link Aggregation
MSTP
- STP
-
Security
- Broadcast storm protection
Rate Limit
Trust access control
Static Port Lock
MAC Sticky
HTTPS/SSL
SSH
RADIUS
TACACS+
Access control list
Login and Password Policy
- Broadcast storm protection
-
Time Management
- SNTP
NTP Server/Client
NTP Authentication
- SNTP
-
Protocols
- IPv4/IPv6
TCP/IP
UDP
ICMP
ARP
RARP
TFTP
DNS
NTP Client
DHCP Server
DHCP Client
802.1X
QoS
HTTPS
HTTP
Telnet
SMTP
SNMPv1/v2c/v3
RMON
Syslog
- IPv4/IPv6
Switch Properties
-
MAC Table Size
- 16 K
-
Jumbo Frame Size
- 9.216 KB
-
Max. No. of VLANs
- 256
-
VLAN ID Range
- VID 1 to 4094
-
IGMP Groups
- 512
-
Priority Queues
- 4
-
Packet Buffer Size
- 1 MB
LED Interface
-
LED Indicators
- PWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL, SYNC
Serial Interface
-
Console Port
- RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
USB Interface
-
USB Connector
- USB Type A (Reserved)
Input/Output Interface
-
Alarm Contact Channels
- 1, Relay output with current carrying capacity of 1 A @ 24 VDC
-
Digital Input Channels
- 1
-
Digital Inputs
- +13 to +30 V for state 1
-30 to +3 V for state 0
Max. input current: 8 mA
- +13 to +30 V for state 1
-
Buttons
- Reset button
DIP Switch Configuration
-
DIP Switches
- Turbo Ring, Master, Coupler, Reserve
Power Parameters
-
Connection
- 2 removable 4-contact terminal block(s)
-
Pre-installed Power Module
- PWR-103-LV-VB-I
-
Note
- The EDS-4008 Series supports modular power supplies. The model names and power parameters are determined by the installed power module.For example:
EDS-4008-T + PWR-100–LV = EDS-4008-LV-T
EDS-4008-T + PWR-105-HV-I = EDS-4008-HV-TIf you install a different power module, refer to the specifications of the corresponding
model. For example, if you replace the power module of the EDS-4008–LV-T
with the PWR-105–HV-I, refer to the specifications of the EDS-4008–HV-T.
- The EDS-4008 Series supports modular power supplies. The model names and power parameters are determined by the installed power module.For example:
-
Input Voltage
- 12/24/48 VDC
Redundant dual inputs
- 12/24/48 VDC
-
Operating Voltage
- 12 to 57 VDC (> 52 VDC for PoE+ output recommended)
-
Input Current
- 12/48 VDC, 7.46/4.27 A or 24 VDC, 7.26 A
-
Power Consumption (Max.)
- Without PoE: 15.84 W
With PoE:
Max. 180 W for total PD power consumption @ 48 VDC input;
Max. 150 W for total PD power consumption @ 24 VDC input;
Max. 62 W for total PD power consumption @ 12 VDC input
- Without PoE: 15.84 W
-
Max. PoE Power Output per Port
- 90 W
-
Overload Current Protection
- Supported
-
Reverse Polarity Protection
- Supported
Physical Characteristics
-
IP Rating
- IP40
-
Dimensions
- 55 x 140 x 122.5 mm (2.17 x 5.51 x 4.82 in)
-
Weight
- 840 g (1.85 lb)
-
Installation
- DIN-rail mounting
Wall mounting (with optional kit)
- DIN-rail mounting
-
Housing
- Metal
Environmental Limits
-
Operating Temperature
- -10 to 60°C (14 to 140°F)
-
Storage Temperature (package included)
- -40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
- 5 to 95% (non-condensing)
Standards and Certifications
-
Industrial Cybersecurity
- IEC 62443-4-1
IEC 62443-4-2
- IEC 62443-4-1
-
Safety
- UL 61010-2-201
EN 62368-1 (LVD)
- UL 61010-2-201
-
EMC
- EN 55032/35
EN 61000-6-2/-6-4
- EN 55032/35
-
EMI
- CISPR 32, FCC Part 15B Class A
-
EMS
- IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
- IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
-
Maritime
- NK
DNV
ABS
LR
- NK
-
Vibration
- IEC 60068-2-6
-
Shock
- IEC 60068-2-27
-
Freefall
- IEC 60068-2-32
-
Railway
- EN 50121-4
-
Traffic Control
- NEMA TS2
-
Power Substation
- IEC 61850-3
IEEE 1613 Class 1
- IEC 61850-3
MTBF
-
Time
- 870,865 hrs
-
Standards
- Telcordia SR332
Warranty
-
Warranty Period
- 5 years