Ethernet Interface
-
Pre-installed Modules
- 4 embedded Gigabit ports
-
Module
- 4 slots for optional 4-port FE/GE modules
-
Slot Combination
- See the LM-7000H module series datasheet for more information.Note: The required power module depends on the choice of LM-7000H module. Refer to the following power/module combination requirements.LM-7000H non-PoE modules:
Any power moduleLM-7000H PoE modules:
PWR-HV-P48, PWR-LV-P48 only
- See the LM-7000H module series datasheet for more information.Note: The required power module depends on the choice of LM-7000H module. Refer to the following power/module combination requirements.LM-7000H non-PoE modules:
-
Standards
- IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
IEEE 802.3x for flow control
IEEE 802.3ad for Port Trunk with LACP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1p for Class of Service
IEEE 802.1X for authentication
IEEE 802.3af/at for PoE/PoE+ output
- IEEE 802.3 for 10BaseT
Ethernet Software Features
-
Management
- IPv4
Flow control
Back Pressure Flow Control
DHCP Server/Client
ARP
RARP
LLDP
Port Mirror
Linkup Delay
SMTP
SNMP Trap
SNMP Inform
SNMPv1/v2c/v3
RMON
TFTP
SFTP
HTTP
HTTPS
Telnet
Syslog
Private MIB
Loopback interface
- IPv4
-
Filter
- GMRP
GVRP
GARP
802.1Q VLAN
IGMP Snooping v1/v2/v3
IGMP Querier
- GMRP
-
Redundancy Protocols
- STP
RSTP
Turbo Ring v2
Turbo Chain
Ring Coupling
Dual-Homing
Link Aggregation
- STP
-
Routing Redundancy
- VRRP
-
Security
- Broadcast storm protection
Rate Limit
Trust access control
Static Port Lock
MAC Sticky
HTTPS/SSL
SSH
RADIUS
TACACS+
Login and Password Policy
- Broadcast storm protection
-
Time Management
- SNTP
NTP Server/Client
NTP Authentication
- SNTP
-
Protocols
- IPv4
TCP/IP
UDP
ICMP
ARP
RARP
TFTP
DNS
NTP Client
DHCP Server
DHCP Client
802.1X
QoS
HTTPS
HTTP
Telnet
SMTP
SNMPv1/v2c/v3
RMON
Syslog
- IPv4
-
Unicast Routing
- OSPF
Static Route
- OSPF
-
MIB
- P-BRIDGE MIB
Q-BRIDGE MIB
IEEE8021-SPANNING-TREE-MIB
IEEE8021-PAE-MIB
IEEE8023-LAG-MIB
LLDP-EXT-DOT1-MIB
LLDP-EXT-DOT3-MIB
SNMPv2-MIB
RMON MIB Groups 1, 2, 3, 9
- P-BRIDGE MIB
Switch Properties
-
MAC Table Size
- 16 K
-
Max. No. of VLANs
- 256
-
VLAN ID Range
- VID 1 to 4094
-
IGMP Groups
- 1024
-
Priority Queues
- 8
-
Packet Buffer Size
- 12 Mbits
Serial Interface
-
Console Port
- RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
USB Interface
-
USB Connector
- USB Type A (Reserved)
Input/Output Interface
-
Digital Input Channels
- 1 (On MGMT Module)
-
Digital Inputs
- +13 to +30 V for state 1
-30 to +3 V for state 0
Max. input current: 8 mA
- +13 to +30 V for state 1
-
Alarm Contact Channels
- 3 (On MGMT, PWR1, PWR2 Module)
Relay output with current carrying capacity of 2 A @ 30 VDC
- 3 (On MGMT, PWR1, PWR2 Module)
Power Parameters
-
Input Voltage
- With PWR-HV-P48 installed:
110/220 VDC, 110 VAC, 60 HZ, 220 VAC, 50 Hz, PoE: 48 VDCWith PWR-LV-P48 installed:
24/48 VDC, PoE: 48 VDCWith PWR-HV-NP installed:
110/220 VDC, 110 VAC, 60 HZ, 220 VAC, 50 HzWith PWR-LV-NP installed:
24/48 VDC
- With PWR-HV-P48 installed:
-
Operating Voltage
- With PWR-HV-P48 installed:
88 to 300 VDC, 90 to 264 VAC, 47 to 63 Hz, PoE: 46 to 57 VDCWith PWR-LV-P48 installed:
18 to 72 VDC (24/48 VDC for hazardous location), PoE: 46 to 57 VDC (48 VDC for hazardous location)With PWR-HV-NP installed:
88 to 300 VDC, 90 to 264 VAC, 47 to 63 HzWith PWR-LV-NP installed:
18 to 72 VDC
- With PWR-HV-P48 installed:
-
Input Current
- With PWR-HV-P48/PWR-HV-NP installed:
Max. 0.30 A @ 110 VDC
Max. 0.11 A @ 220 VDC
Max. 0.60 A @ 110 VAC
Max. 0.29 A @ 220 VACWith PWR-LV-P48/PWR-LV-NP installed:
Max. 3.3 A @ 24 VDC
Max. 0.73A @ 48 VDCEPS (PoE models only):
Max. 8.2 A @ 48 VDCNote: These are the input current ratings for the device with the maximum number of modules installed.
- With PWR-HV-P48/PWR-HV-NP installed:
-
Power Consumption (Max.)
- With PWR-HV-P48/PWR-HV-NP installed:
Max. 33.0 W @ 110 VDC
Max. 24.2 W @ 220 VDC
Max. 32.3 W @ 110 VAC
Max. 27.3 W @ 220 VACWith PWR-LV-P48/PWR-LV-NP installed:
Max. 79.2 W @ 24 VDC
Max. 35.0 W @ 48 VDCNote: These are the maximum power consumption ratings for the device with the maximum number of modules installed.
- With PWR-HV-P48/PWR-HV-NP installed:
-
Max. PoE Power Output per Port
- 36 W
-
Total PoE Power Budget
- Max. 360 W (with one power supply) for total PD consumption at 48 VDC input for PoE systemsMax. 360 W (with one power supply) for total PD consumption at 53 to 57 VDC input for PoE+ systemsMax. 720 W (with two power supplies) for total PD consumption at 48 VDC input for PoE systems
Max. 720 W (with two power supplies) for total PD consumption at 53 to 57 VDC input for PoE+ systems
- Max. 360 W (with one power supply) for total PD consumption at 48 VDC input for PoE systemsMax. 360 W (with one power supply) for total PD consumption at 53 to 57 VDC input for PoE+ systemsMax. 720 W (with two power supplies) for total PD consumption at 48 VDC input for PoE systems
-
Overload Current Protection
- Supported
-
Reverse Polarity Protection
- Supported
Physical Characteristics
-
IP Rating
- IP40
-
Dimensions
- 176 x 115 x 163.25 mm (6.93 x 4.53 x 6.44 in)
-
Weight
- 2500 g (5.51 lb)
-
Installation
- DIN-rail mounting
Wall mounting (with optional kit)
Rack mounting (with optional kit)
- DIN-rail mounting
Environmental Limits
-
Operating Temperature
- -10 to 60°C (14 to 140°F)
-
Storage Temperature (package included)
- -40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
- 5 to 95% (non-condensing)
Standards and Certifications
-
Safety
- EN 62368-1
IEC 62368-1
UL 62368-1
IEC 60950-1
- EN 62368-1
-
EMC
- EN 55032/35
EN 61000-6-2/-6-4
- EN 55032/35
-
EMI
- CISPR 32, FCC Part 15B Class A
-
EMS
- IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
IEC 61000-4-11: Voltage Dips and Voltage Interruptions
- IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
-
Railway
- EN 50121-4
-
Traffic Control
- NEMA TS2
-
Shock
- IEC 60068-2-27
-
Freefall
- IEC 60068-2-31
-
Vibration
- IEC 60068-2-6
-
Hazardous Locations
- Class I Division 2
ATEX
- Class I Division 2
-
Power Substation
- IEEE 1613
IEC 61850-3
- IEEE 1613
MTBF
-
Time
- 1,007,790 hrs
-
Standards
- Telcordia SR332
Warranty
-
Warranty Period
- 5 years